Outdoor Marquee

How to Keep Event Marquee Warm in Winter?

Executive Summary: The Engineering of Controlled Environments

In the B2B sector, operating a marquee during winter is a challenge of systemic engineering. Success is measured by two critical KPIs: Thermal Retention and Structural Redundancy. To transform a temporary structure into a climate-controlled environment that maintains 20°C+ while outside temperatures are sub-zero, one must eliminate thermal bridges and optimize airflow distribution.


Winter Performance Specifications

Component Professional Standard Functional Value
Frame Material 6061-T6 High-Strength Aluminum Resists low-temperature brittleness; maintains elasticity.
Snow Load Capacity 0.5 kn/m² – 1.2 kn/m² Engineered to withstand sustained heavy snowfall.
Roofing System Double-layer Inflatable PVC Creates an air insulation gap to prevent heat loss.
Foundation Elevated Cassette Flooring Isolates the interior from the frozen ground sink.

Combatting the “Cold Bridge” Effect

💡 Technical Definition: Thermal Bridge (Cold Bridge)

A thermal bridge is an area within an object that has higher thermal conductivity than the surrounding materials (such as aluminum beams or ground contact points). In winter, heat follows these paths to escape, leading to high energy costs.

Walling: From PVC Fabric to Sandwich Panels

Standard PVC covers are insufficient for thermal control. For extreme environments, the transition to hard-shell walling is essential.

Feature ABS Hard Walls (Standard) Rock Wool Sandwich Panels
Insulation Logic High-density polymer barrier 50mm high-density core (Mineral Wool/PU)
Energy Efficiency Moderate Superior (Highest R-Value)
Ideal Application Temporary showrooms / Events Long-term warehouses / Ski resort lounges
Value Addition Rapid installation & aesthetics Fire-rated Class A; massive energy savings

Ground Isolation: The Air Plenum Effect

The frozen earth is a significant “heat sink” that will drain warmth from your space.

  • The Solution: Utilize an Elevated Cassette Floor System (as seen in construction phases).

  • The Benefit: Elevating the floor by 10-15cm creates an Air Plenum. This air gap acts as a natural insulator, ensuring the floor remains warm to the touch and providing a dry cavity for utility cables.


Strategic HVAC & Air Distribution

In a Clear Span structure, the distribution of air is as critical as the heating capacity itself.

  • Industrial HVAC Units: Utilize 30HP-50HP external units connected via insulated ducts.

  • Air Flow Organization: It is mandatory to use internal Air Sox (Fabric Ducts). Without them, warm air naturally rises and traps at the roof ridge—causing uneven snow melt—while the ground level remains uncomfortably cold.


Structural Safety: Managing Snow Load and Wind

Engineering Note: At high-altitude sites, frames must utilize 6061-T6 aluminum to handle extreme wind loads (up to 100km/h) and heavy snow accumulation.

  • Active Snow Melting Strategy: Maintain an internal temperature of at least 12°C. This creates a microscopic layer of melt-water between the roof fabric and the snow, encouraging snow to slide off before it exceeds the structural load limit.

  • Anchoring: Frozen soil requires heavy-duty Weight Plates or chemical anchors to ensure stability during winter gales.


Winter Operational Checklist

  • Infiltration Audit: Seal all gaps in wall joints and door frames with weather-stripping to prevent Cold Air Infiltration.

  • Drainage Management: Ensure perimeter gutters are clear to guide melt-water away, preventing ice dams from forming at the base.

  • Power Redundancy: Maintain a backup generator for the HVAC system to prevent structural “cold soak” and snow-load risk during a grid failure.


Engineering a Year-Round Space

As demonstrated in our ski resort projects, a high-quality winter marquee is a masterpiece of materials science. By integrating sandwich panels, elevated flooring, and professional HVAC systems, temporary structures can achieve the comfort and safety standards of permanent buildings.

admin

Recent Posts

Frame Event Marquees for Extreme Cold Winter Outdoor Space

Learn how to operate a winter event marquee at -20°C. From snow load safety to…

2 weeks ago

Cold-Weather Event Marquees for Outdoor Winter

When planning winter outdoor activities, choose cold-resistant event marquees. They offer multiple functions, excellent insulation,…

1 month ago

All Weather Event Marquee for Temporary Exhibition Hall

All Weather Event Marquee offers reliable, rapid temporary event space. Versatile design ensures high ROI…

2 months ago

15x30m Aluminum Event Marquee for Outdoor Meeting

Explore how a Heavy Duty 15m Event Marquee ensures all-day temperature-controlled comfort for 200 guests…

2 months ago

Maximize View: Premier Two Storey Marquees for Golf Course

Elevate your event with a Two Storey Marquee. Discover how our robust, custom-designed structures amplify…

3 months ago

20m Dome Marquee: Visual Impact for Premium Receptions

Learn about its Geodesic Dome Tent structure, Clearspan interior, and premium features for unparalleled brand…

3 months ago